@ECHO OFF
|
|
REM File: ScanlabClassChecker.cmd January 2012
|
|
REM (c) Copyright 2012 by SCANLAB AG. All rights reserved.
|
|
REM
|
|
REM THIS CODE AND INFORMATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY
|
|
REM KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE
|
|
REM IMPLIED WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR
|
|
REM PURPOSE.
|
|
REM
|
|
REM Abstract
|
|
REM This script checks on the registry for a security entry that
|
|
REM allows the built-in user group access to the RTC5 controller.
|
|
REM If necessary, this script adds the particular security entry
|
|
REM to the registry.
|
|
REM
|
|
REM Use
|
|
REM Run this script subsequent to the installation of the WDF driver
|
|
REM for the RTC5 controller.
|
|
|
|
reg query HKLM\System\CurrentControlSet\Control\Class\{D6797410-1514-11d4-BBA5-0050DA39AF40} /ve
|
|
IF %ERRORLEVEL% EQU 1 goto sub_routine_no_entry
|
|
|
|
SET _IsProperties=0
|
|
FOR /F "tokens=7 delims=\" %%G IN ('REG QUERY HKLM\System\CurrentControlSet\Control\Class\{D6797410-1514-11d4-BBA5-0050DA39AF40}') DO (IF %%G==Properties set _IsProperties=1)
|
|
IF %_IsProperties% NEQ 0 goto sub_routine_properties
|
|
REM We need to run elevated to add the required sub-key Properties.
|
|
REM
|
|
REM Do OPENFILES to check for administrative privileges
|
|
OPENFILES > nul
|
|
IF ERRORLEVEL 1 (
|
|
COLOR 0E
|
|
CLS
|
|
ECHO System's registry entry of the SCANLAB device class
|
|
ECHO needs to be updated for the new RTC driver.
|
|
ECHO In order to do this, run this cmd file as an administrator:
|
|
ECHO.
|
|
ECHO Right click on this cmd file and select 'Run as administrator'.
|
|
ECHO.
|
|
PAUSE
|
|
EXIT 1
|
|
)
|
|
|
|
REG ADD HKLM\System\CurrentControlSet\Control\Class\{D6797410-1514-11d4-BBA5-0050DA39AF40}\Properties /v DeviceCharacteristics /t REG_DWORD /d 256
|
|
REG ADD HKLM\System\CurrentControlSet\Control\Class\{D6797410-1514-11d4-BBA5-0050DA39AF40}\Properties /v Security /t REG_BINARY /d 010004900000000000000000000000001400000002004c0003000000000014000000001001010000000000051200000000001800000000100102000000000005200000002002000000001800000000c001020000000000052000000021020000
|
|
REM We need to reboot.
|
|
CLS
|
|
ECHO The update takes effect after a reboot.
|
|
ECHO.
|
|
ECHO.
|
|
COLOR 0E
|
|
SET /P UserChoice=Enter Y to reboot now:
|
|
IF "%UserChoice%"=="" goto sub_routine_no_reboot
|
|
IF /I "%UserChoice%"=="Y" goto sub_routine_reboot
|
|
:sub_routine_no_reboot
|
|
COLOR
|
|
ECHO No reboot invoked.
|
|
ECHO.
|
|
PAUSE
|
|
goto:eof
|
|
|
|
:sub_routine_reboot
|
|
SHUTDOWN /r /d P:4:2
|
|
PAUSE
|
|
goto:eof
|
|
|
|
:sub_routine_properties
|
|
CLS
|
|
ECHO System's registry entry of the SCANLAB device class is up to date.
|
|
ECHO.
|
|
PAUSE
|
|
goto:eof
|
|
|
|
:sub_routine_no_entry
|
|
CLS
|
|
ECHO Nothing to do. The system is ready for a RTC installation.
|
|
ECHO.
|
|
PAUSE
|
|
goto:eof
|