#pragma once
|
|||
|
#include "BaseClient.h"
|
|||
|
#include "../config/ConfigManager.h"
|
|||
|
#include "../LanguageManager.h"
|
|||
|
#include <unordered_map>
|
|||
|
|
|||
|
class DoluyoChillerstat
|
|||
|
{
|
|||
|
public:
|
|||
|
explicit DoluyoChillerstat() {
|
|||
|
tempRealtimeValue = 0;
|
|||
|
runInfo = 0;
|
|||
|
isRun = false;
|
|||
|
alarmInfo = 0;
|
|||
|
tempSettingValue = 0;
|
|||
|
isLevelAlarm = false;
|
|||
|
}
|
|||
|
|
|||
|
string GetRunInfo() {
|
|||
|
string str = "";
|
|||
|
switch (runInfo) {
|
|||
|
case 0:str = _(u8"待机"); break;
|
|||
|
case 2:str = _(u8"关机过程"); break;
|
|||
|
case 4:str = _(u8"制冷运行"); break;
|
|||
|
case 5:str = _(u8"制热运行"); break;
|
|||
|
case 6:str = _(u8"化霜运行"); break;
|
|||
|
}
|
|||
|
return str;
|
|||
|
}
|
|||
|
|
|||
|
string GetAlarmInfo() {
|
|||
|
string str = "";
|
|||
|
switch (alarmInfo)
|
|||
|
{
|
|||
|
case 0:str = _(u8"无故障"); break;
|
|||
|
case 1:str = _(u8"提示故障"); break;
|
|||
|
case 2:str = _(u8"停机故障"); break;
|
|||
|
}
|
|||
|
return str;
|
|||
|
}
|
|||
|
|
|||
|
public:
|
|||
|
BaseStat baseStat;
|
|||
|
float tempRealtimeValue; //水箱温度
|
|||
|
unsigned short runInfo; //运行消息 0:待机 2:关机过程 4:制冷运行 5:制热运行 6:化霜运行
|
|||
|
unsigned char isRun; //开关机
|
|||
|
unsigned short alarmInfo; //故障消息 0:无故障 1:提示故障 2:停机故障
|
|||
|
float tempSettingValue; //设定温度
|
|||
|
bool isLevelAlarm; //液位报警
|
|||
|
};
|
|||
|
|
|||
|
class HansChillerstat //冷水机
|
|||
|
{
|
|||
|
public:
|
|||
|
HansChillerstat() {
|
|||
|
m_WaterOutTemp = 0.0f;
|
|||
|
m_Flow = 0.0f;
|
|||
|
m_SettingTemp = 0.0f;
|
|||
|
|
|||
|
m_RunIndicate = false;
|
|||
|
m_WorkIndicate = false;
|
|||
|
m_IsAlarm = false;
|
|||
|
m_CompressorIndicate = false;
|
|||
|
m_WaterPumpIndicate = false;
|
|||
|
m_HeaterIndicate = false;
|
|||
|
m_FanIndicate = false;
|
|||
|
m_SolenoidValveIndicate = false;
|
|||
|
m_FlowAlarm = false;
|
|||
|
m_TempAlarm = false;
|
|||
|
m_PressureAlarm = false;
|
|||
|
m_WaterLevelAlarm = false;
|
|||
|
m_LowTempErrorIndicate = false;
|
|||
|
m_TempUndulateIndicate = false;
|
|||
|
|
|||
|
m_TempSensorAlarm = false;
|
|||
|
m_SolenoidValveAlarm = false;
|
|||
|
m_HeaterExceptionIndicate = false;
|
|||
|
m_IOSignalIndicate = false;
|
|||
|
m_PhaseSeqAlarm = false;
|
|||
|
m_CompressorStartFreqAlarm = false;
|
|||
|
m_IO0Alarm = false;
|
|||
|
m_IO1Alarm = false;
|
|||
|
m_IO2Alarm = false;
|
|||
|
m_IO3Alarm = false;
|
|||
|
m_IO4Alarm = false;
|
|||
|
}
|
|||
|
~HansChillerstat() {}
|
|||
|
public:
|
|||
|
BaseStat baseStat;
|
|||
|
|
|||
|
float m_WaterOutTemp; //出水温度
|
|||
|
float m_Flow; //流量
|
|||
|
float m_SettingTemp; //设置温度
|
|||
|
|
|||
|
bool m_RunIndicate; //运行指示
|
|||
|
bool m_WorkIndicate; //工作正常指示
|
|||
|
bool m_IsAlarm; //报警
|
|||
|
bool m_CompressorIndicate; //压缩机指示
|
|||
|
bool m_WaterPumpIndicate; //水泵指示
|
|||
|
bool m_HeaterIndicate; //加热器指示
|
|||
|
bool m_FanIndicate; //风机指示
|
|||
|
bool m_SolenoidValveIndicate; //电磁阀指示
|
|||
|
bool m_FlowAlarm; //流量报警
|
|||
|
bool m_TempAlarm; //温度报警
|
|||
|
bool m_PressureAlarm; //压力报警
|
|||
|
bool m_WaterLevelAlarm; //液位报警
|
|||
|
bool m_LowTempErrorIndicate; //低温错误指示
|
|||
|
bool m_TempUndulateIndicate; //温度波动指示
|
|||
|
|
|||
|
bool m_TempSensorAlarm; //温度传感器故障报警
|
|||
|
bool m_SolenoidValveAlarm; //电磁阀故障报警
|
|||
|
bool m_HeaterExceptionIndicate; //加热器异常指示
|
|||
|
bool m_IOSignalIndicate; //IO信号指示
|
|||
|
bool m_PhaseSeqAlarm; //相序报警
|
|||
|
bool m_CompressorStartFreqAlarm; //压缩机起动频繁报警
|
|||
|
bool m_IO0Alarm; //IO0错误报警
|
|||
|
bool m_IO1Alarm; //IO1错误报警
|
|||
|
bool m_IO2Alarm; //IO2错误报警
|
|||
|
bool m_IO3Alarm; //IO3错误报警
|
|||
|
bool m_IO4Alarm; //IO4错误报警
|
|||
|
};
|
|||
|
|
|||
|
class TongFeiStat {
|
|||
|
|
|||
|
public:
|
|||
|
BaseStat m_BaseStat;
|
|||
|
|
|||
|
bool m_IsLowVoltageAlarm; //低压报警
|
|||
|
bool m_IsHydraulicFailure; //液路故障
|
|||
|
bool m_IsLevelFailure; //液位故障
|
|||
|
bool m_IsLiquidPumpAlarm; //液泵热继电器报警
|
|||
|
bool m_IsPressAlarm; //压机热继电器报警
|
|||
|
bool m_IsElectricHeatingFailure; //电加热故障
|
|||
|
bool m_IsAntifreezeAlarm; //防冻报警
|
|||
|
bool m_IsLiquidTempTooHigh; //液温太高
|
|||
|
bool m_IsLiquidTempProbeFailure; //液温温度探头故障
|
|||
|
bool m_IsEffluentTempProbeFailure; //出液温度探头故障
|
|||
|
bool m_IsAmbientTempProbeFailure; //环境温度探头故障
|
|||
|
bool m_IsCondensationTempProbeFailure; //冷凝温度探头故障
|
|||
|
bool m_IsEvaporationInletTempProbeFailure; //蒸发进口温度探头故障
|
|||
|
bool m_IsEvaporationOutletTempProbeFailure; //蒸发出口温度探头故障
|
|||
|
bool m_IsCondensationTempTooHigh; //冷凝温度过高
|
|||
|
bool m_IsPhaseOrderError; //相序错误
|
|||
|
bool m_IsPowerFailure; //电源故障
|
|||
|
bool m_IsCompressorFailure; //压缩机故障
|
|||
|
bool m_IsAmbientTempTooHigh; //环境温度太高
|
|||
|
bool m_IsAmbientTempException; //环境温度异常
|
|||
|
|
|||
|
int m_AlarmState; //故障状态
|
|||
|
float m_RoomTempSettingValue; //室温同调预设温度
|
|||
|
float m_ConstantTempSettingValue; //恒温预设温度
|
|||
|
int m_WorkMode; //工作模式
|
|||
|
int m_RefrigerationMethod; //制冷方式
|
|||
|
float m_LiquidAlarmTemp; //出液报警温度
|
|||
|
int m_UnitStatus; //机组状态
|
|||
|
|
|||
|
float m_LiquidTempProbe; //液温温度探头
|
|||
|
float m_EffluentTempProbe; //出液温度探头
|
|||
|
float m_AmbientTempProbe; //环境温度探头
|
|||
|
float m_CondensationTempProbe; //冷凝温度探头
|
|||
|
float m_EvaporationInletTempProbe; //蒸发进口温度探头
|
|||
|
float m_EvaporationOutletTempProbe; //蒸发出口温度探头
|
|||
|
float m_WorkingFrequency; //运行频率
|
|||
|
float m_OverHeatingValue; //过热度
|
|||
|
float m_EEV1;
|
|||
|
float m_EEV2;
|
|||
|
float m_CondensingFanRatio; //冷凝风机比例
|
|||
|
float m_ElectricHeatingRatio; //电加热比例
|
|||
|
float m_FlowRate; //流量
|
|||
|
};
|
|||
|
|
|||
|
|
|||
|
#pragma pack(1)
|
|||
|
class DoluyoChillerParam
|
|||
|
{
|
|||
|
public:
|
|||
|
explicit DoluyoChillerParam()
|
|||
|
: m_tempRealtimeValue(new FloatData("tempRealtimeValue",u8"水箱温度"))
|
|||
|
, m_runInfo(new UShortData("runInfo",u8"水箱温度"))
|
|||
|
, m_isRun(new BoolData("isRun","水箱温度"))
|
|||
|
, m_alarmInfo(new UShortData("alarmInfo","水箱温度"))
|
|||
|
, m_tempSettingValue(new FloatData("tempSettingValue","水箱温度"))
|
|||
|
, m_isLevelAlarm(new BoolData("isLevelAlarm","水箱温度")){
|
|||
|
}
|
|||
|
|
|||
|
string GetRunInfo() {
|
|||
|
string str = "";
|
|||
|
switch (m_runInfo->GetValue()) {
|
|||
|
case 0:str = _(u8"待机"); break;
|
|||
|
case 2:str = _(u8"关机过程"); break;
|
|||
|
case 4:str = _(u8"制冷运行"); break;
|
|||
|
case 5:str = _(u8"制热运行"); break;
|
|||
|
case 6:str = _(u8"化霜运行"); break;
|
|||
|
}
|
|||
|
return str;
|
|||
|
}
|
|||
|
|
|||
|
string GetAlarmInfo() {
|
|||
|
string str = "";
|
|||
|
switch (m_alarmInfo->GetValue())
|
|||
|
{
|
|||
|
case 0:str = _(u8"无故障"); break;
|
|||
|
case 1:str = _(u8"提示故障"); break;
|
|||
|
case 2:str = _(u8"停机故障"); break;
|
|||
|
}
|
|||
|
return str;
|
|||
|
}
|
|||
|
|
|||
|
public:
|
|||
|
BaseStat baseStat;
|
|||
|
|
|||
|
char m_startFlag; //成员变量开始标记
|
|||
|
//float tempRealtimeValue; //水箱温度
|
|||
|
FloatData* m_tempRealtimeValue; //水箱温度
|
|||
|
//unsigned short runInfo; //运行消息 0:待机 2:关机过程 4:制冷运行 5:制热运行 6:化霜运行
|
|||
|
UShortData* m_runInfo; //运行消息 0:待机 2:关机过程 4:制冷运行 5:制热运行 6:化霜运行
|
|||
|
//bool isRun; //开关机
|
|||
|
BoolData* m_isRun; //开关机
|
|||
|
//unsigned short alarmInfo; //故障消息 0:无故障 1:提示故障 2:停机故障
|
|||
|
UShortData* m_alarmInfo; //故障消息 0:无故障 1:提示故障 2:停机故障
|
|||
|
//float tempSettingValue; //设定温度
|
|||
|
FloatData* m_tempSettingValue; //设定温度
|
|||
|
//bool isLevelAlarm; //液位报警
|
|||
|
BoolData* m_isLevelAlarm; //液位报警
|
|||
|
char m_endFlag; //成员变量结束标记
|
|||
|
};
|
|||
|
|
|||
|
class HansChillerParam //冷水机
|
|||
|
{
|
|||
|
public:
|
|||
|
HansChillerParam()
|
|||
|
: m_WaterOutTemp(new FloatData("WaterOutTemp", u8"出水温度"))
|
|||
|
, m_Flow(new FloatData("Flow", u8"流量"))
|
|||
|
, m_SettingTemp(new FloatData("SettingTemp", u8"设置温度"))
|
|||
|
, m_RunIndicate(new BoolData("RunIndicate", u8"运行指示"))
|
|||
|
, m_WorkIndicate(new BoolData("WorkIndicate", u8"工作正常指示"))
|
|||
|
, m_IsAlarm(new BoolData("IsAlarm", u8"报警"))
|
|||
|
, m_CompressorIndicate(new BoolData("CompressorIndicate", u8"压缩机指示"))
|
|||
|
, m_WaterPumpIndicate(new BoolData("WaterPumpIndicate", u8"水泵指示"))
|
|||
|
, m_HeaterIndicate(new BoolData("HeaterIndicate", u8"加热器指示"))
|
|||
|
, m_FanIndicate(new BoolData("FanIndicate", u8"风机指示"))
|
|||
|
, m_SolenoidValveIndicate(new BoolData("SolenoidValveIndicate", u8"电磁阀指示"))
|
|||
|
, m_FlowAlarm(new BoolData("FlowAlarm", u8"流量报警"))
|
|||
|
, m_TempAlarm(new BoolData("TempAlarm", u8"温度报警"))
|
|||
|
, m_PressureAlarm(new BoolData("PressureAlarm", u8"压力报警"))
|
|||
|
, m_WaterLevelAlarm(new BoolData("WaterLevelAlarm", u8"液位报警"))
|
|||
|
, m_LowTempErrorIndicate(new BoolData("LowTempErrorIndicate", u8"低温错误指示"))
|
|||
|
, m_TempUndulateIndicate(new BoolData("TempUndulateIndicate", u8"温度波动指示"))
|
|||
|
, m_TempSensorAlarm(new BoolData("TempSensorAlarm", u8"温度传感器故障报警"))
|
|||
|
, m_SolenoidValveAlarm(new BoolData("SolenoidValveAlarm", u8"电磁阀故障报警"))
|
|||
|
, m_HeaterExceptionIndicate(new BoolData("HeaterExceptionIndicate", u8"加热器异常指示"))
|
|||
|
, m_IOSignalIndicate(new BoolData("IOSignalIndicate", u8"IO信号指示"))
|
|||
|
, m_PhaseSeqAlarm(new BoolData("PhaseSeqAlarm", u8"相序报警"))
|
|||
|
, m_CompressorStartFreqAlarm(new BoolData("CompressorStartFreqAlarm", u8"压缩机起动频繁报警"))
|
|||
|
, m_IO0Alarm(new BoolData("IO0Alarm", u8"IO0错误报警"))
|
|||
|
, m_IO1Alarm(new BoolData("IO1Alarm", u8"IO1错误报警"))
|
|||
|
, m_IO2Alarm(new BoolData("IO2Alarm", u8"IO2错误报警"))
|
|||
|
, m_IO3Alarm(new BoolData("IO3Alarm", u8"IO3错误报警"))
|
|||
|
, m_IO4Alarm(new BoolData("IO4Alarm", u8"IO4错误报警"))
|
|||
|
{
|
|||
|
}
|
|||
|
~HansChillerParam(){}
|
|||
|
public:
|
|||
|
BaseStat baseStat;
|
|||
|
|
|||
|
char m_startFlag; //成员变量开始标记
|
|||
|
|
|||
|
FloatData* m_WaterOutTemp; //出水温度
|
|||
|
FloatData* m_Flow; //流量
|
|||
|
FloatData* m_SettingTemp; //设置温度
|
|||
|
|
|||
|
BoolData* m_RunIndicate; //运行指示
|
|||
|
BoolData* m_WorkIndicate; //工作正常指示
|
|||
|
BoolData* m_IsAlarm; //报警
|
|||
|
BoolData* m_CompressorIndicate; //压缩机指示
|
|||
|
BoolData* m_WaterPumpIndicate; //水泵指示
|
|||
|
BoolData* m_HeaterIndicate; //加热器指示
|
|||
|
|
|||
|
BoolData* m_FanIndicate; //风机指示
|
|||
|
BoolData* m_SolenoidValveIndicate; //电磁阀指示
|
|||
|
BoolData* m_FlowAlarm; //流量报警
|
|||
|
BoolData* m_TempAlarm; //温度报警
|
|||
|
BoolData* m_PressureAlarm; //压力报警
|
|||
|
BoolData* m_WaterLevelAlarm; //液位报警
|
|||
|
BoolData* m_LowTempErrorIndicate; //低温错误指示
|
|||
|
BoolData* m_TempUndulateIndicate; //温度波动指示
|
|||
|
|
|||
|
BoolData* m_TempSensorAlarm; //温度传感器故障报警
|
|||
|
BoolData* m_SolenoidValveAlarm; //电磁阀故障报警
|
|||
|
BoolData* m_HeaterExceptionIndicate; //加热器异常指示
|
|||
|
BoolData* m_IOSignalIndicate; //IO信号指示
|
|||
|
BoolData* m_PhaseSeqAlarm; //相序报警
|
|||
|
BoolData* m_CompressorStartFreqAlarm; //压缩机起动频繁报警
|
|||
|
BoolData* m_IO0Alarm; //IO0错误报警
|
|||
|
BoolData* m_IO1Alarm; //IO1错误报警
|
|||
|
BoolData* m_IO2Alarm; //IO2错误报警
|
|||
|
BoolData* m_IO3Alarm; //IO3错误报警
|
|||
|
BoolData* m_IO4Alarm; //IO4错误报警
|
|||
|
|
|||
|
char m_endFlag; //成员变量结束标记
|
|||
|
};
|
|||
|
|
|||
|
class TongFeiParam {
|
|||
|
|
|||
|
public:
|
|||
|
TongFeiParam()
|
|||
|
: m_IsLowVoltageAlarm(new BoolData("IsLowVoltageAlarm", u8"低压报警"))
|
|||
|
, m_IsHydraulicFailure(new BoolData("IsHydraulicFailure", u8"液路故障"))
|
|||
|
, m_IsLevelFailure(new BoolData("IsLevelFailure", u8"液位故障"))
|
|||
|
, m_IsLiquidPumpAlarm(new BoolData("IsLiquidPumpAlarm", u8"液泵热继电器报警"))
|
|||
|
, m_IsPressAlarm(new BoolData("IsPressAlarm", u8"压机热继电器报警"))
|
|||
|
, m_IsElectricHeatingFailure(new BoolData("IsElectricHeatingFailure", u8"电加热故障"))
|
|||
|
, m_IsAntifreezeAlarm(new BoolData("IsAntifreezeAlarm", u8"防冻报警"))
|
|||
|
, m_IsLiquidTempTooHigh(new BoolData("IsLiquidTempTooHigh", u8"液温太高"))
|
|||
|
, m_IsLiquidTempProbeFailure(new BoolData("IsLiquidTempProbeFailure", u8"液温温度探头故障"))
|
|||
|
, m_IsEffluentTempProbeFailure(new BoolData("IsEffluentTempProbeFailure", u8"出液温度探头故障"))
|
|||
|
, m_IsAmbientTempProbeFailure(new BoolData("IsAmbientTempProbeFailure", u8"环境温度探头故障"))
|
|||
|
, m_IsCondensationTempProbeFailure(new BoolData("IsCondensationTempProbeFailure", u8"冷凝温度探头故障"))
|
|||
|
, m_IsEvaporationInletTempProbeFailure(new BoolData("IsEvaporationInletTempProbeFailure", u8"蒸发进口温度探头故障"))
|
|||
|
, m_IsEvaporationOutletTempProbeFailure(new BoolData("IsEvaporationOutletTempProbeFailure", u8"蒸发出口温度探头故障"))
|
|||
|
, m_IsCondensationTempTooHigh(new BoolData("IsCondensationTempTooHigh", u8"冷凝温度过高"))
|
|||
|
, m_IsPhaseOrderError(new BoolData("IsPhaseOrderError", u8"相序错误"))
|
|||
|
, m_IsPowerFailure(new BoolData("IsPowerFailure", u8"电源故障"))
|
|||
|
, m_IsCompressorFailure(new BoolData("IsCompressorFailure", u8"压缩机故障"))
|
|||
|
, m_IsAmbientTempTooHigh(new BoolData("IsAmbientTempTooHigh", u8"环境温度太高"))
|
|||
|
, m_IsAmbientTempException(new BoolData("IsAmbientTempException", u8"环境温度异常"))
|
|||
|
, m_AlarmState(new IntData("AlarmState", u8"故障状态"))
|
|||
|
, m_RoomTempSettingValue(new FloatData("RoomTempSettingValue", u8"室温同调预设温度"))
|
|||
|
, m_ConstantTempSettingValue(new FloatData("ConstantTempSettingValue", u8"恒温预设温度"))
|
|||
|
, m_WorkMode(new IntData("WorkMode", u8"工作模式"))
|
|||
|
, m_RefrigerationMethod(new IntData("RefrigerationMethod", u8"制冷方式"))
|
|||
|
, m_LiquidAlarmTemp(new FloatData("LiquidAlarmTemp", u8"出液报警温度"))
|
|||
|
, m_UnitStatus(new IntData("UnitStatus", u8"机组状态"))
|
|||
|
, m_LiquidTempProbe(new FloatData("LiquidTempProbe", u8"液温温度探头"))
|
|||
|
, m_EffluentTempProbe(new FloatData("EffluentTempProbe", u8"出液温度探头"))
|
|||
|
, m_AmbientTempProbe(new FloatData("AmbientTempProbe", u8"环境温度探头"))
|
|||
|
, m_CondensationTempProbe(new FloatData("CondensationTempProbe", u8"冷凝温度探头"))
|
|||
|
, m_EvaporationInletTempProbe(new FloatData("EvaporationInletTempProbe", u8"蒸发进口温度探头"))
|
|||
|
, m_EvaporationOutletTempProbe(new FloatData("EvaporationOutletTempProbe", u8"蒸发出口温度探头"))
|
|||
|
, m_WorkingFrequency(new FloatData("WorkingFrequency", u8"运行频率"))
|
|||
|
, m_OverHeatingValue(new FloatData("OverHeatingValue", u8"过热度"))
|
|||
|
, m_EEV1(new FloatData("EEV1", u8"蒸发出口温度探头"))
|
|||
|
, m_EEV2(new FloatData("EEV2", u8"蒸发出口温度探头"))
|
|||
|
, m_CondensingFanRatio(new FloatData("CondensingFanRatio", u8"冷凝风机比例"))
|
|||
|
, m_ElectricHeatingRatio(new FloatData("ElectricHeatingRatio", u8"电加热比例"))
|
|||
|
, m_FlowRate(new FloatData("FlowRate", u8"流量"))
|
|||
|
{
|
|||
|
|
|||
|
}
|
|||
|
|
|||
|
BaseStat m_BaseStat;
|
|||
|
|
|||
|
char m_startFlag; //成员变量开始标记
|
|||
|
BoolData* m_IsLowVoltageAlarm; //低压报警
|
|||
|
BoolData* m_IsHydraulicFailure; //液路故障
|
|||
|
BoolData* m_IsLevelFailure; //液位故障
|
|||
|
BoolData* m_IsLiquidPumpAlarm; //液泵热继电器报警
|
|||
|
BoolData* m_IsPressAlarm; //压机热继电器报警
|
|||
|
BoolData* m_IsElectricHeatingFailure; //电加热故障
|
|||
|
BoolData* m_IsAntifreezeAlarm; //防冻报警
|
|||
|
BoolData* m_IsLiquidTempTooHigh; //液温太高
|
|||
|
BoolData* m_IsLiquidTempProbeFailure; //液温温度探头故障
|
|||
|
BoolData* m_IsEffluentTempProbeFailure; //出液温度探头故障
|
|||
|
BoolData* m_IsAmbientTempProbeFailure; //环境温度探头故障
|
|||
|
BoolData* m_IsCondensationTempProbeFailure; //冷凝温度探头故障
|
|||
|
BoolData* m_IsEvaporationInletTempProbeFailure; //蒸发进口温度探头故障
|
|||
|
BoolData* m_IsEvaporationOutletTempProbeFailure; //蒸发出口温度探头故障
|
|||
|
BoolData* m_IsCondensationTempTooHigh; //冷凝温度过高
|
|||
|
BoolData* m_IsPhaseOrderError; //相序错误
|
|||
|
BoolData* m_IsPowerFailure; //电源故障
|
|||
|
BoolData* m_IsCompressorFailure; //压缩机故障
|
|||
|
BoolData* m_IsAmbientTempTooHigh; //环境温度太高
|
|||
|
BoolData* m_IsAmbientTempException; //环境温度异常
|
|||
|
IntData* m_AlarmState; //故障状态
|
|||
|
FloatData* m_RoomTempSettingValue; //室温同调预设温度
|
|||
|
FloatData* m_ConstantTempSettingValue; //恒温预设温度
|
|||
|
IntData* m_WorkMode; //工作模式
|
|||
|
IntData* m_RefrigerationMethod; //制冷方式
|
|||
|
FloatData* m_LiquidAlarmTemp; //出液报警温度
|
|||
|
IntData* m_UnitStatus; //机组状态
|
|||
|
FloatData* m_LiquidTempProbe; //液温温度探头
|
|||
|
FloatData* m_EffluentTempProbe; //出液温度探头
|
|||
|
FloatData* m_AmbientTempProbe; //环境温度探头
|
|||
|
FloatData* m_CondensationTempProbe; //冷凝温度探头
|
|||
|
FloatData* m_EvaporationInletTempProbe; //蒸发进口温度探头
|
|||
|
FloatData* m_EvaporationOutletTempProbe; //蒸发出口温度探头
|
|||
|
FloatData* m_WorkingFrequency; //运行频率
|
|||
|
FloatData* m_OverHeatingValue; //过热度
|
|||
|
FloatData* m_EEV1;
|
|||
|
FloatData* m_EEV2;
|
|||
|
FloatData* m_CondensingFanRatio; //冷凝风机比例
|
|||
|
FloatData* m_ElectricHeatingRatio; //电加热比例
|
|||
|
FloatData* m_FlowRate; //流量
|
|||
|
|
|||
|
char m_endFlag; //成员变量开始标记
|
|||
|
};
|
|||
|
#pragma pack()
|
|||
|
|
|||
|
class ChillerClient:public TcpClient
|
|||
|
{
|
|||
|
public:
|
|||
|
ChillerClient(void* pconfig = nullptr, int* tp = nullptr);
|
|||
|
~ChillerClient();
|
|||
|
|
|||
|
void GetDoluyoStat(DoluyoChillerstat& stat);
|
|||
|
void GetHansStat(HansChillerstat& stat);
|
|||
|
void GetTongFeiStat(TongFeiStat& stat);
|
|||
|
//void InitCommand();
|
|||
|
void DrawUI();
|
|||
|
private:
|
|||
|
//void static ProcDoluyoInfo(void* pobject, Command* pcommand);
|
|||
|
//void static ProcDoluyoSettingValue(void* pobject, Command* pcommand);
|
|||
|
//void static ProcDoluyoReadTargeValue(void* pobject, Command* pcommand);
|
|||
|
//void SetDoluyoTargetTempValue(float value);
|
|||
|
|
|||
|
//void static ProcHansInfo(void* pobject, Command* pcommand);
|
|||
|
//void SetHansTargetTempValue(float value);
|
|||
|
|
|||
|
//void static ProcTongfeiAlarmInputInfo(void* pobject, Command* pcommand);
|
|||
|
//void static ProcTongfeiAlarmStateInfo(void* pobject, Command* pcommand);
|
|||
|
//void static ProcTongfeiUserParamsInfo(void* pobject, Command* pcommand);
|
|||
|
//void static ProcTongfeiAnaShowInfo(void* pobject, Command* pcommand);
|
|||
|
//void static ProcTongfeiAnaShowInfo2(void* pobject, Command* pcommand);
|
|||
|
//void static ProcTongfeianaShowInfo3(void* pobject, Command* pcommand);
|
|||
|
|
|||
|
public:
|
|||
|
bool m_IsShowUI;
|
|||
|
private:
|
|||
|
DoluyoChillerParam m_DoluyoChillerStat;
|
|||
|
HansChillerParam m_HansChillerstat;
|
|||
|
TongFeiParam m_TongFeiStat;
|
|||
|
int* m_Type;
|
|||
|
};
|
|||
|
|
|||
|
|